The ABB Aurora Power-One range of solar inverters includes a variety of different sized solar inverters to accommodate nearly any on-grid application. As with all ranges of solar inverters, the ABB Aurora Power-One range can display a number of fault codes in certain circumstances.
The following is a list of error codes, messages, causes, and solutions from the user manual for the ABB Aurora Power-One Inverter. Following is a list of error and alarm messages that the ABB Aurora Power-One inverters may display, as well as procedures for resolving potential issues and troubleshooting advice. If you require further assistance call on: 1300445124
Message |
Warning |
Error
|
Description |
---|---|---|---|
Sun Low | W001 | Input Voltage under threshold Input voltage under threshold (when off) |
|
Input OC | E001 | Input Over-current | |
Input UV | W002 | Input Under-voltage | |
Input OV | E002 | Input Over-voltage | |
Int. Error | E003 | No parameters | |
Bulk OV | E004 | Bulk Over-voltage | |
Int. Error | E005 | Communication Error | |
Out OC | E006 | Output Over-current | |
Int. Error | E007 | IGBT Sat | |
Sun Low | W011 | Bulk Under-voltage | |
Int. Error | E009 | Internal Error | |
Grid Fail | W003 | Grid Fail Wrong grid parameters |
|
Int. Error | E010 | Bulk Low | |
Int. Error | E011 | Ramp Fail | |
DC/DC Fail | E012 | DcDc Error revealed by inverter DcDc fault detected by inverter |
|
Wrong Mode | E013 | Wrong Input setting (Singe instead of dual) Wrong Input setting (Single instead of dual channel) |
|
Over Temp. | E014 | Over-temperature Internal temperature too high |
|
Cap. Fault | E015 | Bulk Capacitor Fail Bulk capacitor fault |
|
Inv. Fault | E016 | Inverter fail revealed by DcDc Inverter fault detected by DcDc |
|
Int. Error | E017 | Start Timeout | |
Ground F. | E018 | I leak fail Leakage current fault |
|
Int. Error | E019 | I leak Sensor fail Leakage current fault |
|
Int. Error | E020 | DcDc relay fail DcDc relay fault |
|
Int. Error | E021 | Inverter relay fail Inverter relay fault |
|
Int. Error | E022 | Autotest Timeout | |
Int. Error | E023 | Dc-Injection Error | |
Grid OV | W004 | Output Over-voltage | |
Grid UV | W005 | Output Under-voltage | |
Grid OF | W006 | Output Over-frequency | |
Grid UF | W007 | Output Under-frequency | |
Z Grid HI | W008 | Z grid out of range Impedence outside range |
|
Int. Error | E024 | Unknown Error – Internal Error |
|
————- | E025 | Riso Low (Log Only) Low insulation resistance (Log only) |
|
Int. Error | E026 | Vref Error Wrong reference voltage (VRef) |
|
Int. Error | E027 | Vgrid Measures Fault Grid voltage (VGrid) misreading |
|
Int. Error | E028 | Fgrid Measures Fault Grid frequency (FGrid) misreading |
|
Int. Error | E029 | Zgrid Measures Fault | |
Int. Error | E030 | Ileak Measures Fault Leak current (ILeak) misreading |
|
Int. Error | E031 | Wrong V Measure Voltage (V) misreading |
|
Int. Error | E032 | Wrong I Measure Current (I) misreading |
|
Fan Fail | W010 | Fan Fail (no disconnection) Fan Faulty (Log Only) |
|
Int. Error | E033 | Under Temperature Internal Temperature |
|
E034 | Interlock Fail (Not Used) | ||
E035 | Remote Off Remote power-off |
||
E036 | Vout Avg Average output voltage outside range |
||
W012 | Clock Battery Low (No disconnection) Clock battery low (not operating) |
||
W013 | Clock Failure (No disconnection) Clock faulty (not operating) |